판매용 중고 PERKIN ELMER Lambda 950 #9119552

이 품목은 이미 판매 된 것 같습니다. 아래 유사 제품을 확인하거나 연락해 주십시오. EMC 의 숙련된 팀이 이 제품을 찾을 수 있습니다.

ID: 9119552
Spectrometer P/N: L6020036 Lambda 950 STD Detector Assy Polarizer Assy-L900 Software: (UV Winlab 5.2.0 / Accessory software UV Winlab V1.1.3 / Software utilities Ver 7.00) Bandwidth: 0.05 nm - 5.00 nm in 0.01 nm increments UV/Vis range 0.20 nm - 20.00 nm in 0.04 nm increments NIR range Fixed resolution, constant energy or slit programming Light Source: Pre-aligned tungsten-halogen and deuterium Optics: Split Beam Photodetector: photomultiplier Photometric Range UV/Vis: 8 A NIR: 6 A Wavelength Range: 175 to 900 nm N2 purge required below 185 nm Power Requirements: 90 VAC - 250 VAC, 50/60 Hz; 250 VA Beam Splitting System: Chopper (46+ Hz, Cycle: Dark/Sample/ Dark/Reference, Chopper Segment Signal Correction) UV/Vis resolution: 2 A At 220 nm, 10 g/l NaI ASTM method: At 340 nm, 50 mg/l NaNO2 ASTM method: At 370 nm, 50 mg/l NaNO2 ASTM method: At 1420 nm, H20 1 cm path length: At 2365 nm, CHCl3 1 cm path length: Wavelength accuracy: UV/Vis: ± 0.080 nm NIR: ± 0.300 nm Wavelength reproducibility: UV/Vis (Deuterium lamp lines) NIR (Deuterium lamp lines) Standard deviation of 10 measurements UV/Vis Standard deviation of 10 measurements NIR Photometric accuracy: Double Aperture Method 1 A: ± 0.0006 A Double Aperture Method 0.5 A; ± 0.0003 A NIST 1930D Filters 2 A: ± 0.0030 A NIST 930D Filters 1 A: ± 0.0030 A NIST 930D Filters 0.5 A: ± 0.0020 A K2Cr2O7-Solution USP/DAP method: ± 0.0080 A Photometric linearity: Addition of filters UV/Vis at 546.1 nm, 2 nm slit, 1 second integration time At 1.0 A: ± 0.0060 A At 2.0 A: ± 0.0160 A At 3.0 A: ± 0.0050 A Photometric reproducibility Standard deviation for 10 measurements, 2 nm slit, 1 second integration time 1 A with NIST 930D Filter at 546.1 nm: = 0.00016 A 0.5 A with NIST 930D Filter at 546.1 nm: = 0.00008 A 0.3 A with NIST 930D Filter at 546.1 nm: = 0.00008 A Photometric display: Unlimited Photometric stability: After warm-up at 500 nm, 0 A, 2 nm slit, 2 second integration time, peak to peak: = 0.0002 A/h Baseline flatness: 190 nm - 3100 nm, 2 nm slit 0.20 second integration time UV/Vis, no smoothing applied 0.24 second integration time NIR, no smoothing applied: ± 0.0008 A Purging: Optics: Yes Sample compartment: Yes Light beam: 90 mm above the base plate 120 mm beam separation 3 mm - 12 mm beam height.
PERKIN ELMER Lambda 950은 연구, 품질 분석 및 생산 제어에서 정확한 자외선-가시성 (UV-Vis) 측정을 제공하는 고정밀 분광계입니다. 업계에서 가장 광범위한 애플리케이션을 위한 탁월한 성능을 제공하며, 가장 까다로운 요구 사항인 분광 분석 (Spectroscopic Analysis) 을 충족할 수 있는 강력한 성능과 유연성을 제공합니다. 람다 950 (Lambda 950) 은 가장 좋은 수준의 감도와 스펙트럼 해상도를 제공하는 직경이 큰 광학 구성 요소가있는 회절-격자 광학으로 구성됩니다. 이를 통해 질적 (qualitative) 애플리케이션과 양적 (quantitative) 애플리케이션 모두에 필요한 정확한 정보를 제공할 수 있습니다. 전체 스펙트럼 스캔의 경우 최대 16 파장 포인트, 더 빠른 측정의 경우 2 파장 포인트로 190 ~ 950 나노 미터 (nm) 사이를 측정 할 수 있습니다. 사용이 간편한 직관적인 인터페이스를 통해 PC 또는 노트북에 직접 연결할 수 있습니다 (영문). 소프트웨어 제어 옵션을 사용하면 빠르고 정확하게 보정 및 데이터를 수집할 수 있습니다. 샘플 정렬은 자동화되어 매우 정밀하고 정확합니다. 자동 슬릿 크기 선택 기능 (Automatic slit size selection facility) 을 통해 최대 해상도를 허용하여 측정 정확도를 더욱 높일 수 있습니다. PERKIN ELMER Lambda 950에는 원격 액세스를위한 내장 광섬유, 정확한 시간 기반 측정을위한 노출 타이머, 안정적인 판독을위한 온도 조절 인클로저 등 다양한 추가 기능이 있습니다. 첨단 광학, 고감도, 고해상도 이 분광사진계가 실험실에서 최고의 성능을 제공하도록 합니다.
아직 리뷰가 없습니다