판매용 중고 TERADYNE Catalyst #145333

TERADYNE Catalyst
ID: 145333
Tester Configuration: 2 processor system Processor 1: 1280 MHz sparcv9 (online) Processor 2: 1280 MHz sparcv9 (online) PCI based system Terabus is present TCI is present CATALYST_TH 1 BACKPLANE A #Slot Type Num XptA XptB Name 2 879-858-35 0 # 23 24 PLFD CC 3 879-858-25 0 # 21 22 PLFS CC 4 000-000-00 0 # 19 20 EMPTY 5 879-792-01 0 # 17 18 TIME CC 6 879-857-01 0 # 15 16 PMM CC-01 7 000-000-00 0 # 13 14 EMPTY 8 949-658-00 0 # 11 12 LFAC DUAL CC 9 949-658-00 0 # 9 10 LFAC DUAL CC 10 949-681-50 0 # 7 8 VHFAWG400 DIFF CC 11 949-672-50 0 # 5 6 VHFDIG CC 14 803-594-00 0 # 25 26 UHFSRC CC 15 803-596-05 0 # 27 28 UWPORT 16 803-595-00 0 # 29 30 UWMM 17 949-643-00 0 # 31 32 TJD CC 18 803-596-05 0 # 33 34 UWPORT 19 803-594-00 0 # 35 36 UHFSRC CC 20 803-594-00 0 # 37 38 UHFSRC CC 21 000-000-00 0 # 39 40 EMPTY 22 879-858-25 0 # 41 42 PLFS CC 23 879-858-35 0 # 43 44 PLFD CC 1 949-669-00 0 # 3 0 HAS (Left HAS LA669-00) 13 949-668-00 0 # 0 0 CATALYST HAC 12 949-667-00 0 # 0 0 DIF 24 949-669-01 0 # 4 0 HAS (Right HAS LA669-01) END RF_PIPES 1 pipe-name slot schan description Z8A 15 1 # UWPORT (OSP) Z7A 15 2 # UWPORT (OSP) Z6A 15 3 # UWPORT (OSP) Z5A 15 4 # UWPORT (OSP) Z4A 18 1 # UWPORT (OSP) Z3A 18 2 # UWPORT (OSP) Z2A 18 3 # UWPORT (OSP) Z1A 18 4 # UWPORT (OSP) END RF_CONNECTIONS 1 RF pipe connections between channel cards slot schan slot schan 14 1 to 15 5 16 3 to 15 7 19 1 to 18 5 20 1 to 18 6 16 1 to 18 7 END Up to 4 Precision AC Card Cages are allowed PRECISION_AC 1 Slot Type Num Name 1 949-718-00 0 # PLFDIG TCI 2 879-764-01 0 # PLFSRC 3 879-779-00 0 # 1M SMEM 4 949-660-01 0 # LFACDIG 5 949-660-00 0 # LFACDIG 6 949-659-00 0 # LFACSRC 7 949-659-00 0 # LFACSRC 8 949-671-01 0 # PACS CAGE INT END PRECISION_AC 2 Slot Type Num Name 1 949-718-00 0 # PLFDIG TCI 2 879-764-01 0 # PLFSRC 3 879-779-00 0 # 1M SMEM 4 949-827-00 0 # VHFAWG 5 949-664-00 0 # VHFDIG MF 6 949-320-00 0 # UWMS 7 949-608-00 0 # VHFAWG 8 949-671-01 0 # PACS CAGE INT END Up to 8 Universal Backplane/Synch Power Subsystem cages are allowed For the Synch Power Subsystem: Slot Type Name Instr1 # Instr2 # Ammeter # Instr1 # - insrument connected to the first two matrix lines Instr2 # - insrument connected to the last two matrix lines Ammeter # - ammeter connection to AVOID errors, put NO 0 if no instrument is connected. UB_SPS_CAGE 1 Slot Type Num Name 1 879-802-02 0 # UB_SPS_802 2 517-301-00 0 # UB_APU 3 517-301-00 0 # UB_APU 4 517-301-00 0 # UB_APU 5 517-301-00 0 # UB_APU 6 517-301-00 0 # UB_APU 7 517-301-00 0 # UB_APU 8 517-301-00 0 # UB_APU 9 517-301-00 0 # UB_APU 10 517-301-00 0 # UB_APU 11 517-301-00 0 # UB_APU 12 517-301-00 0 # UB_APU 13 517-301-00 0 # UB_APU 14 879-925-01 0 # UB_60_V_SRC MAT 1 15 879-925-01 0 # UB_60_V_SRC DUT 1 16 879-925-01 0 # UB_60_V_SRC MAT 2 17 879-925-01 0 # UB_60_V_SRC MAT 3 18 879-925-01 0 # UB_60_V_SRC MAT 5 19 879-925-01 0 # UB_60_V_SRC DUT 5 21 879-690-00 0 # UB_ASY 22 517-300-01 0 # UB_TJ300 END HSD100_CHAN_CAGE 1 Slot Type Num Fld1 Fld2 Name 1 949-921-01 0 # HSD CDM 400 2 949-921-01 0 # HSD CDM 400 3 949-921-01 0 # HSD CDM 400 4 949-921-01 0 # HSD CDM 400 5 949-820-10 0 # HSD CSB 6 949-921-01 0 # HSD CDM 400 7 949-921-01 0 # HSD CDM 400 8 949-921-01 0 # HSD CDM 400 9 949-921-01 0 # HSD CDM 400 END HSD100_CHAN_CAGE 2 Slot Type Num Fld1 Fld2 Name 5 949-820-00 0 # HSD CSB END CATALYST_TH 1 BACKPLANE B Slot Type Num Name 29 949-626-10 0 # HSD THS 43 949-625-00 0 # HSD DTH 44 949-625-00 0 # HSD DTH 45 949-625-00 0 # HSD DTH 46 949-625-00 0 # HSD DTH 47 949-626-20 0 # HSD THS/HCLK 48 949-625-00 0 # HSD DTH 49 949-625-00 0 # HSD DTH 50 949-625-00 0 # HSD DTH 51 949-625-00 0 # HSD DTH 61 949-625-00 0 # HSD DTH 62 949-625-00 0 # HSD DTH 63 949-625-00 0 # HSD DTH 64 949-625-00 0 # HSD DTH 65 949-626-00 0 # HSD THS 66 949-625-00 0 # HSD DTH 67 949-625-00 0 # HSD DTH 68 949-625-00 0 # HSD DTH 69 949-625-00 0 # HSD DTH 74 949-626-10 0 # HSD THS END Trigger Switch Yard Note: The logical slot numbers below correspond to the physical slot numbers only for test systems which contain a TSY card cage. In test systems which contain an SCS/TSY card cage the mapping is: Logical TSY slot (below) Physical slot 1 -> 2 3 -> 1 TSY CAGE Slot Type Num Name 1 879-655-02 0 # TSY 2 000-000-00 0 # EMPTY 3 000-000-00 0 # EMPTY 4 000-000-00 0 # EMPTY END Time Subsystem TIME_SUBSYSTEM # Board ID Name 879-793-00 # TMS Timer 879-794-01 # TMS Counter 879-795-01 # TMS Support END # The UWMS option resides in the PACS cage and is composed of two # plug-in modules that may reside in one of three locations A, B or C. # A zero in the type field indicates no plug-in module. # PACS_UW <n> - indicates PACS cage number of these UWMS options # Slot - indicates slot number and module position for this UWMS option # Type - board identification number # AWG Num - AWG instrument number connected to this UWMS option # UHFSRC Num - UHF instrument number that has this UWMS option # MODSRC Num - First or second MODSRC connected to above UHFSRC # PACS_UW 2 # AWG UHFSRC MODSRC #Slot Type Rev Date Num Num Num Name 6 949-320-00 A 9943-0 2 1 1 # UWMS 6A 949-330-00 A 9944-0 # UWMS UP CONV 6B 000-000-00 0 0000-0 6C 949-333-00 C 9948-0 # UWMS MUX END # # # The UWPORT option modules are composed of plug-in modules. # The names list in the first column indicate the presence of # the option modules for the uwport. # UWPORT_OPTIONS_HEAD 1 # # Name Slot Type Rev Num Date PORT 15 803-596-05 A 1 # 0122-0 NOISE 15 733-104-00 A 1 # 9923-0 PORT 18 803-596-05 A 2 # 0122-0 NOISE 18 733-104-00 A 2 # 9923-0 END # # DC Subsystem - # # SRC <NUM> [1 - 13] # (sources 1-5 are MATRIX sources 1-5 # sources 6-13 are DUT sources 1-8) # HCU <NUM> *[1 - 4] # REF HCU <NUM> *[1 - 4] # HVSRC <NUM> *[1 - 4] # PWRSRC <NUM> [1 - 4] # DATABITS <NUM> - <NUM> [1 - 192] # # ** These instruments share the same seven-slot cage -- only one # instrument is allowed per slot. # DC_SUBSYSTEM # UBVI 60 1 ( 60V V/I Source in Universal Backplane 1 : slot 14) # UBVI 60 2 ( 60V V/I Source in Universal Backplane 1 : slot 16) # UBVI 60 3 ( 60V V/I Source in Universal Backplane 1 : slot 17) HCU 4 # UBVI 60 5 ( 60V V/I Source in Universal Backplane 1 : slot 18) # UBVI 60 6 ( 60V V/I Source in Universal Backplane 1 : slot 15) HCU 7 HCU 8 HCU 9 # UBVI 60 10 ( 60V V/I Source in Universal Backplane 1 : slot 19) DATABITS 1 - 48 # UB_MATRIX # # Testhead 1 # XPTs UB Cage Slot Type # 1-4 1 2 APU # 5-8 1 3 APU # 9-12 1 4 APU # 13-16 1 5 APU # 17-20 1 6 APU # 21-24 1 7 APU # 25-28 1 8 APU # 29-32 1 9 APU # 33-36 1 10 APU # 37-40 1 11 APU # 41-44 1 12 APU # 45-48 1 13 APU END.
테라 딘 카탈리스트 (TERADYNE Catalyst) 는 반도체 테스트 솔루션의 비용과 복잡성을 최소화하기 위해 설계된 강력하고 고급 최종 테스트 장비입니다. 테스트 시간을 최적화하고, 설치 공간 요구 사항을 줄이고, 장치의 수명 품질을 향상시키도록 설계되었습니다. 촉매 테스트 시스템 (Catalyst test system) 은 최신 기술을 사용하여 테스트 프로세스를 자동화하고 복잡한 테스트 프로그램에 의존하지 않는 장치 내 인텔리전스 (in-unit intelligence) 와 자동화 (automation) 를 사용하여 비용을 절감합니다. 고속 테스트 복제, 병렬 프로그래밍, 통합 진단 및 인텔리전스를 사용하며, 최고 800 MHz의 업계 최고의 테스트 속도를 제공합니다. TERADYNE Catalyst 테스트 머신은 스캐닝 기능, 고성능 (high-operator) 액세스, 고급 장애 위치, 여러 제조업체의 테스트 장치 등 다양한 솔루션을 제공합니다. 원터치 (One-touch) 테스트 설정과 더 빠른 테스트 프로그래밍을 위한 Flexforce 지원을 제공합니다. 또한 Catalyst에서 장애가 발생한 장치를 감지하고 고객에게 배송하지 못하도록 하는 QA 전체 QA (Exhaustive Sensory I/O) 지원을 철저히 실시간으로 모니터링할 수 있는 Quality Yield Controller도 포함되어 있습니다. 또한 고급 디버깅 기능을 통해 보다 빠르고 효율적으로 실험할 수 있습니다. 이러한 기능에는 높은 수준의 추적 가능성 및 전체 자동 테스트 분석이 포함됩니다. 여기에는 자산 수준 하드웨어 솔루션 및 자동화된 테스트 생성 및 실행 기능이 포함됩니다. 이 모델은 또한 정적, 동적, 논리적 장애 범위, 메모리 테스트 및 실시간 모니터링을 지원합니다. TERADYNE Catalyst 최종 테스트 장비는 오늘날 반도체 기업의 높은 수요 및 자동화 솔루션을 충족하도록 설계되었습니다. 테스트 프로세스를 간소화하는 강력한 테스트 시스템을 제공합니다. 고급 자동화, 진단 및 인텔리전스 (Intelligence) 기능을 제공하여 신속하게 장애를 파악하고, 테스트 시간을 줄이고, 비용을 절감하고, 제품의 품질을 향상시킵니다.
아직 리뷰가 없습니다